| Availability: | |
|---|---|
| Quantity: | |
hongjin
Product Features:
This product features multiple workstations, an integrated alignment guide rail, and a strong structural design with high frequency response. It has passed high-acceleration shock testing, and the impact half-sine waveform meets test specifications.
| Number of stations: | 4-station |
| Acceleration range: | 10g-3000g |
| Impact platform dimensions: | (1500×1500×2000mm) (Available dimensions subject to change) |
| Impact platform weight: | 300kg |
| Operating conditions: | a. Power supply voltage: 220V ±10% AC, 50Hz |
| b. Ambient temperature: 0°C-40°C | |
| c. Relative humidity: ≤90% (25°C) | |
| Range: | 50g-1000g (×0.1) |
| 500g-10,000g (×1) | |
| 5,000g-100,000g (×10) | |
| Resolution: | 1g (50g-1000g) |
| Response time: | 1s |
| Pulse width > 10mS, pulse rise time > 20μS | |
| Power supply: | AC 220V ±10%, 50Hz |
| Dimensions: | 270×135×76 mm³ |
| Host voltage: | 380V |
| Monitor voltage: | 200-240V 55Hz |
| Maximum frequency: | 72/min times |
| Maximum impact: | 2550C |
| Minimum operating force: | 33HZ |
| Fixed fixture: | Standard rail for scopes |
| Power consumption: | 1.5KVA |
| Measurement error: | ≤5%±3 |
| Host power: | 1500W |
| Reduction ratio: | 1:20 |
| Minimum frequency: | 25/min |
| Minimum impact force: | 1550G |








Product Features:
This product features multiple workstations, an integrated alignment guide rail, and a strong structural design with high frequency response. It has passed high-acceleration shock testing, and the impact half-sine waveform meets test specifications.
| Number of stations: | 4-station |
| Acceleration range: | 10g-3000g |
| Impact platform dimensions: | (1500×1500×2000mm) (Available dimensions subject to change) |
| Impact platform weight: | 300kg |
| Operating conditions: | a. Power supply voltage: 220V ±10% AC, 50Hz |
| b. Ambient temperature: 0°C-40°C | |
| c. Relative humidity: ≤90% (25°C) | |
| Range: | 50g-1000g (×0.1) |
| 500g-10,000g (×1) | |
| 5,000g-100,000g (×10) | |
| Resolution: | 1g (50g-1000g) |
| Response time: | 1s |
| Pulse width > 10mS, pulse rise time > 20μS | |
| Power supply: | AC 220V ±10%, 50Hz |
| Dimensions: | 270×135×76 mm³ |
| Host voltage: | 380V |
| Monitor voltage: | 200-240V 55Hz |
| Maximum frequency: | 72/min times |
| Maximum impact: | 2550C |
| Minimum operating force: | 33HZ |
| Fixed fixture: | Standard rail for scopes |
| Power consumption: | 1.5KVA |
| Measurement error: | ≤5%±3 |
| Host power: | 1500W |
| Reduction ratio: | 1:20 |
| Minimum frequency: | 25/min |
| Minimum impact force: | 1550G |