Availability: | |
---|---|
Quantity: | |
hongjin
Product features:
1. The left and right scales have zero adjustment and measurement functions, and the bending of the tool can be clearly seen through the pointer display.
2. The transparent acrylic detachable protective device prevents the tool from breaking during the test and causing harm to people.
3. The maximum sample size is 400mm, which meets the testing needs of various samples.
4. The weight and test size can be customized according to the user's specific test needs.
Test principle:
Install the sample without hanging weights, adjust the left and right pointers to zero, then apply a certain weight to the blade, use the manual joystick to rotate the center axis until the end clamp is lifted from the track, and maintain for 10 seconds, then put the joystick back, unload the load, read the offset angle from the left dial, turn the specimen over, repeat the test once, and observe the damage of the specimen after two tests. If a permanent deformation of 3° occurs, the sample is unqualified.
Test weight: | 10N±0.2N (3 weights) |
Balance block: | 89*30*15mm (error 0.03MM) |
Plastic parallel ruler: | 380*8mm |
Scale plate: | 180mm*350mm (outer ring angle 50°) |
Dimensions: | 607*386*470mm |
Standard of use: | GB/T 15067.2-2016, 1S0 8442-1-1997 |
Product features:
1. The left and right scales have zero adjustment and measurement functions, and the bending of the tool can be clearly seen through the pointer display.
2. The transparent acrylic detachable protective device prevents the tool from breaking during the test and causing harm to people.
3. The maximum sample size is 400mm, which meets the testing needs of various samples.
4. The weight and test size can be customized according to the user's specific test needs.
Test principle:
Install the sample without hanging weights, adjust the left and right pointers to zero, then apply a certain weight to the blade, use the manual joystick to rotate the center axis until the end clamp is lifted from the track, and maintain for 10 seconds, then put the joystick back, unload the load, read the offset angle from the left dial, turn the specimen over, repeat the test once, and observe the damage of the specimen after two tests. If a permanent deformation of 3° occurs, the sample is unqualified.
Test weight: | 10N±0.2N (3 weights) |
Balance block: | 89*30*15mm (error 0.03MM) |
Plastic parallel ruler: | 380*8mm |
Scale plate: | 180mm*350mm (outer ring angle 50°) |
Dimensions: | 607*386*470mm |
Standard of use: | GB/T 15067.2-2016, 1S0 8442-1-1997 |